¡Envío GRATIS a TODO el Perú desde S/89!  Ver más

menú

0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional
portada Real-time Filtering of Physiological Tremor for Microsurgery. Physiological Tremor Robotic Compensation (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
184
Encuadernación
Tapa Blanda
Dimensiones
21.0 x 14.8 x 1.1 cm
Peso
0.24 kg.
ISBN13
9783346289896

Real-time Filtering of Physiological Tremor for Microsurgery. Physiological Tremor Robotic Compensation (en Inglés)

Kalyana Veluvolu (Autor) · Sivanagaraja Tatinati (Autor) · Grin Verlag · Tapa Blanda

Real-time Filtering of Physiological Tremor for Microsurgery. Physiological Tremor Robotic Compensation (en Inglés) - Veluvolu, Kalyana ; Tatinati, Sivanagaraja

Libro Físico

S/ 378,52

S/ 757,04

Ahorras: S/ 378,52

50% descuento
  • Estado: Nuevo
Origen: Estados Unidos (Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el Lunes 17 de Junio y el Miércoles 26 de Junio.
Lo recibirás en cualquier lugar de Perú entre 2 y 5 días hábiles luego del envío.

Reseña del libro "Real-time Filtering of Physiological Tremor for Microsurgery. Physiological Tremor Robotic Compensation (en Inglés)"

Document from the year 2020 in the subject Engineering - Robotics, grade: 2, course: PhD, language: English, abstract: The work conducted in this dissertation focuses on issues that are related to the accurate and real-time separation of physiological tremor components from the sensed motion. This dissertation mainly focused on developing new algorithms and techniques for accurate modeling and prediction of physiological tremor components ( the filtering and modeling system) for the hand-held instruments. The methods developed in the course of this dissertation were validated with the physiological tremor database collected from micro-surgeons and novice subjects. Further, the methods were experimentally validated with the bench tests conducted on hand-held instrument, iTrem. Precision, robustness, dexterity, and intelligence are the design indices for current generation surgical robotics. In microsurgeries, physiological tremor - an intrinsic hand motion with amplitude of 100 m - is a major impediment for surgeons' to perform delicate and fine motor tasks in sub-millimeter space. To augment the required precision and dexterity into normal microsurgical workflow by compensating the tremor in real-time, hand-held robotic instruments are developed. The working principle of a typical handheld instrument involves subsequent execution of three steps 1) sensing its own motion with inertial sensors, 2) filtering the involuntary motion from the sensed motion, and 3) actuate the surgical end-effectors (instrument tip) based on the filtered involuntary motions to compensate the tremor motion. Generally, digital filters are employed to filter out the noise components and subsequently extract the tremor motion from the whole motion. As a result, a time-varying and unknown delay in the range of 20 to 200ms (depends on the variant of the filter) is introduced into the tremor compensation proceedings, which in turn, adversely affects the tremor compensation performance. Ide

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes